Home | PZ
Diplexer 7
Diplexer 7 Med Image

Qualification Information:

  • Vibration per MIL-STD-810E; 6000 miles and vibration levels per Table 514.4-AXIX of MIL-STD-810E
  • Shock
    • 18 saw tooth shock pulses of 40 +/- 4 G's, duration 11 milliseconds applied in both directions of each of three axes. MIL-STD 810E Method 516.3 procedure I
    • Ballistic Shock per MIL-S-901D


  • Specifications
Part Number: 7CZSP-255/305-30-0
Center Frequency: Rx: 256.5 MHz Nominal
Tx: 305.5 MHz Nominal
Passband: Rx: 243 to 270 MHz
Tx: 292 to 318 MHz
Insertion Loss: 1.0 dB over Rx/Tx Passbands
VSWR: Rx: 1.5:1 Over Passband
Tx: 1.4:1 Over Passband
Stopband Rx: -50 dB over 0 to 130 MHz
-40 dB over 130 to 190 MHz
-65 dB over 292 to 300 MHz
-73 dB over 300 to 675 MHz
Tx: -50 dB over 0 to 270 MHz
-50 dB over 360 to 900 MHz
Isolation: -80 dB over 2 to 228 MHz
-50 dB over 243 to 270 MHz
-50 dB over 292 to 400 MHz
Power Handling:  100 Watts
Weight: 2 lbs./ .91 kg
Operating Temperature: 40° to +65°C
Size (in/mm): 1.54 x 3.73 x 5.55 / 39.12 x 94.74 x 140.97
Environmental Testing:  As Required